UT5470
Technical Specification
| Model | UT5472 | UT5470 |
| Key Specifications | ||
| Channels | 1 | |
| AC Voltage | — | 0.050–10.000 kV |
| DC Voltage | 0.050–12.000 kV | — |
| AC Current | — | 0.001–20 mA |
| DC Current | 0.1 μA–10 mA | — |
| Insulation Resistance | 0.1 MΩ–50 GΩ | — |
| Technical Details | ||
| Test Mode | DCW / IR | ACW / OSC |
| Hipot Voltage Accuracy | ±(2% rdg + 20 V) | |
| Hipot Current Accuracy | ±(2% rdg + 3 digits) | |
| Distortion degree | — | <3% |
| Output ripple | <5% | — |
| Minimum charging current | 0–350 μA, Auto / Manual | — |
| Arc detection | Off / Level 1–9 | Level 1–9 (<7 kV); Level 1–8 (≥7 kV) |
| IR Voltage Range | 0.050–6.000 kV | — |
| IR Voltage Accuracy | ±(2% rdg + 20 V) | — |
| Resistance Range | 0.1 MΩ–50 GΩ | — |
| Resistance Accuracy | 50–999 V: ±(15% rdg + 10 digits); 1000–6000 V: 1–9.999 MΩ ±(3% rdg + 10 digits), 10–99.99 MΩ ±(5% rdg + 10 digits), 100–999.9 MΩ ±(7% rdg + 10 digits), 1–50 GΩ ±(15% rdg + 10 digits) | — |
| Features | ||
| Step Connection Without Power Interruption | Yes | |
| Electrical Shock Protection | Yes | |
| Scanner Interface | Yes | |
| Self Detection | Yes | |
| Communication Protocol | SCPI, Modbus-RTU | |
| Open/Short Circuit Check | No | Yes |
| Breakdown Voltage Test | Yes | |
| Storage | 100 files / 200 steps | |
| General Information | ||
| Display | 5-inch capacitive touchscreen LCD | |
| Interface | RS-232, RS-485, LAN, USB Host, Handler | |
| Power | 100–120 / 200–240 VAC, <500 VA | |
| Product Net Weight | 25 kg | |
| Product Dimensions (W×H×D) | 430 × 134.3 × 435 mm | |
| Standard Quantity Per Carton | 1 pc | |
| Warranty | 3 Years | |