MSO1000HD

MSO1000HD series high-resolution oscilloscope has the maximum bandwidth of 250 MHz, the maximum sample rate of 2.5 GSa/s, and is equipped with 4 analog channels and 16 digital channels, with the memory depth of up to 100 Mpts. MSO1000HD series adopts exclusive Ultra Phosphor 3.0 technology, achieving the waveform capture rate of up to 200,000 wfms/s, with 256 levels of gray temperature colors, and features an innovative digital trigger system with high trigger sensitivity and low jitter

150 MHz~250 MHz

BANDWIDTH

4

ANALOG CHANNELS

2.5GSa/s

REAL-TIME SAMPLE RATE

100Mpts

MAX. MEMORY DEPTH

1,000,000wfms/s

WAVEFORM CAPTURE RATE

16

DIGITAL CHANNELS

KEY FEATURES

Model
MSO1254HD-S

FEATURES

Brand New Appearance Design

Double-sided slim design for a modern and compact factor
Dimensions:28.2cm×17.5cm×4.9cm

Type-C for Power Supply

MSO1000HD series adopts the latest Type-C power supply method. When no power source is available outdoors, it can be powered by a portable charger

Enhanced resolution of 16-bit

Higher precision, lower noise floor. In 16-bit high-resolution mode, by combining 12-bit ADC with 4-bit ERES (enhanced resolution), the measurement accuracy is significantly improved, finely displaying the intricate details of waveforms. This effectively suppresses out-of-band noise and reduces the oscilloscope’s inherent noise interference with the real signal, thereby ensuring a more precise measurement experience while increasing the sampling bits.

Versatile Testing Equipment

-Oscilloscopes
-Logic Analyzer
-Function/Arbitrary Waveform Generator
-Spectrum Analyzer
-Protocol Analyzer
-Power Analyzer
-Bode plot Analyzer
-High Precision Frequency Counter
-Digital Voltmeter

Ultra Phosphor 3.0

Supports 8-channel parallel graph mapping, the processing rate is up to 20 Gbps, the waveform capture rate is up to 200,000 wfms/s, and up to 1,000,000 wfms/s in the sequence mode.

56 Types: Measurement, Statistics, Trend Graphs

56 types of precise parameter automatic measurements covering multiple dimensions such as voltage, frequency, phase, and power. It also integrates advanced parameter statistics and trend graph visualization analysis functions, providing a comprehensive and multi-dimensional display of signal characteristic changes, achieving professional-level deep insights and efficient data interpretation.

Protocol decoding and triggering

Supports 7 types of mainstream protocols, including
-Embedded: UART, I2C, SPI
-Automobile: CAN, CAN-FD, LIN
-Audio: Audio

Spectrum Analyzer

-Standard enhanced FFT with up to 1 Mpts
for 4-channel signal analysis
-Frequency range: 0 to 1.25 GHz
-Waterfall curve
-4 traces and 4 detections
-Mark type: Auto, manual, and threshold
-Marker point list

Power Analysis

Input Analysis
-Power Quality
-Harmonic Analysis
-Inrush Current
Switching Analysis
-Switching Loss
-Safe Operating Area (SOA)
-Slew Rate
-Steady-State On-Resistance
Output Analysis
-Ripple Analysis
-Modulation Analysis
-Power Efficiency
-Transient response
-ON/OFF time

MODEL

Model Bandwidth Analog Channels Real-time Sample Rate Max. Memory Depth Waveform Capture Rate Digital Channels

MSO1254HD-S

250MHz 4 2.5GSa/s 100Mpts 1,000,000wfms/s 16

MSO1254HD

250MHz 4 2.5GSa/s 100Mpts 1,000,000wfms/s 16

MSO1154HD-S

150MHz 4 2.5GSa/s 100Mpts 1,000,000wfms/s 16

MSO1154HD

150MHz 4 2.5GSa/s 100Mpts 1,000,000wfms/s 16

Technical Specification

Model MSO1254HD-S MSO1254HD MSO1154HD-S MSO1154HD
Key Specifications
Bandwidth 250 MHz 250 MHz 150 MHz 150 MHz
Channels 4 analog; 16 digital
Sample Rate 2.5 GSa/s (single channel); 1.25 GSa/s (dual channels); 625 MSa/s (all channels)
Vertical Resolution 12-bit; ERes up to 16-bit
Max. Memory Depth 100 Mpts
Max. Waveform Capture Rate 200,000 wfms/s; 1,000,000 wfms/s sequence mode
Technical Details
Rise Time ≤1.40 ns (typ.) ≤1.40 ns (typ.) ≤2.20 ns (typ.) ≤2.20 ns (typ.)
Time Base Scale 2 ns/div to 1 ks/div
Vertical Scale 500 μV/div to 10 V/div
Input Impedance (1 MΩ ±2%) || 17 pF
Features
Auto Measurements 56 parameters
GEN Single-channel, 25 MHz, 200 MSa/s — Single-channel, 25 MHz, 200 MSa/s —
Protocol Analysis Count 7
Included Bus Protocols RS-232/422/485/UART, I²C, SPI, CAN, LIN, CAN-FD, Audio
DVM 4-digit
Frequency Counter 7-digit
Spectrum Analysis Enhanced FFT, up to 1 Mpts
Power Analysis 14 types (standard) 12 types (standard) 14 types (standard) 12 types (standard)
General Information
Display 7-inch HD capacitive touchscreen, 1024×600
Interface USB Host/Device, LAN
Power 100–240 VAC / USB Type-C power
Product Net Weight 1.56 kg
Product Dimensions (W×H×D) 282 × 175 × 49 mm
Standard Quantity Per Carton 1 pc
Certification CE, cETLus
Warranty 3 years

DATA SHEET

QUICKSTART GUIDE

MANUAL

SOFTWARE

Software package

UNI-T SDK

Current Version: V2.3 | 2025/8/8

Release Notes

Software Development Kit, a collection of tools and resources that developers use to do second development with UNI-T instruments which have programmable feature.

FIRMWARE

Software package

MSO1000HD Firmware

Current Version: V1.01.0081 | 2026/1/15

Release Notes

MSO1000HD Firmware …………………………………………………………………………………………………………………………………………………… Version: V1.01.0081 Date: 2026/1/8 Compatibility: hardware versions V1.03 and above Update: 1. Optimized CSV file time handling 2. Added configurable fastest roll time base 3. Expanded power analysis to 12 types 4. Added SCPI SOCKET function 5. SCPI waveform memory readout now supports up to 1M …………………………………………………………………………………………………………………………………………………… Version: V1.00.0068 Date: 2025/7/17 Compatibility: hardware versions V1.03 and above Update: 1. Fixed the issue where the baseline does not disappear in Single and Normal modes. 2. Fixed the issue that the oscilloscope freezes when saving search events in AUTO trigger mode with a 1 MHz, 3 V sine wave input. 3. Fixed the issue that the oscilloscope freezes after pressing "Add Measurement". 4. Fixed the issue that the waveform does not refresh when the auxiliary interface is enabled in ROLL mode. 5. Fixed some known BUGs. ……………………………………………………………………………………………………………………………………………………
Software package

MSO1000HD Firmware

Current Version: V1.00.0068 | 2025/7/21

Release Notes

MSO1000HD Firmware …………………………………………………………………………………………………………………………………………………… Version: V1.00.0068 Date: 2025/7/17 Compatibility: hardware versions V1.03 and above Update: 1. Fixed the issue where the baseline does not disappear in Single and Normal modes. 2. Fixed the issue that the oscilloscope freezes when saving search events in AUTO trigger mode with a 1 MHz, 3 V sine wave input. 3. Fixed the issue that the oscilloscope freezes after pressing "Add Measurement". 4. Fixed the issue that the waveform does not refresh when the auxiliary interface is enabled in ROLL mode. 5. Fixed some known BUGs. ……………………………………………………………………………………………………………………………………………………

OTHER DOWNLOADS

Software package

Device Manager

Current Version: V2.8 | 2025/7/21

Release Notes

Device Manager …………………………………………………………………………………………………………………………………………………… Version: 2.8 Date: 2025/7/21 1. Added support for UTG4000X and UTS7000A series models. 2. Reconstructed the UI display of Arbitrary Wave Editor V2.0. 3. Added a zoom window function to Waveform Analysis Software V2.0. 4. Fixed some known bugs. …………………………………………………………………………………………………………………………………………………… Version: 2.7 Date: 2025/4/28 -new: add USG3000、USG5000、UPO1000HD、MSO1000HD、UPO2000HD、MSO5000HD Series -fix: some known bugs …………………………………………………………………………………………………………………………………………………… Version: 2.6 Date: 2024/7/31 -new: add MSO3000HD Series, UTS3000A series -fix: some known bugs -update: 1. New Arbitrary Waveform Editor V2.0 version. 2. New waveform editor software V2.0 version of the waveform recording and measurement, deep storage waveform analysis and other functions. …………………………………………………………………………………………………………………………………………………… Version: 2.4 Date: 2024/4/25 -new: add MSO2000X Series, MSO3000X Series, UTS5000A series -fix: some known bugs …………………………………………………………………………………………………………………………………………………… Version: 2.2 Date: 2024/3/20 Supported Devices: Waveform Generators: UTG9000T Series, UTG900E Series, UTG1000X Series, UTG4000A Series(HW2.0), UTG1000X Series, UTG2000X Series Oscilloscopes: UTD2102CEX+ Series, UPO1000CS Series, UPO1000 Series, MSO2000E Series, MSO3000E Series, MSO2000X Series, MSO3000X Series Spectrum/Signal Analyzers: UTS3000B Series, UTS1000B Series, UTS5000A Series Please note that these updates are aimed at improving the performance and stability of the software. We recommend updating to the latest version for a better user experience. If you encounter any issues while using the software, please contact our technical support team. Thank you for your support and usage of our software!

Videos

MSO1000HD Series NPI Video

MSO1000HD Series NPI Video